Mcquay model number tonnage.

McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ...

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

Slide out fan (7 to 20 Ton [24.6 to 70.3 kW] units) • For easy access and serviceability. 7.5 to 12.5 Ton [26.4 to 44.0 kW] Unit (15 to 20 Ton [52.8 to 70.3 kW] Unit Not Shown) Gas Heat • Tubular heat exchanger with in-shot burn-ers for maximum heat transfer. • Two-stage gas valve with direct spark ignition provides greater efficiency on 7.5Here's an example of a Guardian model number: GCGE 36 S211A. A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the system is 3 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons.3. Wherever vertical rise occurs in the suction piping, the minimum tonnage Table 8. Liquid line accessory kits (when supplied by McQuay) 886-580896A-06 NOTE: % Larger capacity expansion valve in liquid line accessory kit is used for circuit #2. Page 9: Refrigerant Charge HOT GAS BYPASS COMPONENTS to bring the pressure to a maximum of 125 psig.Model AWV. The Pathfinder is the most efficient machine on the market today - the first air-cooled screw chiller with IPLVs capable of exceeding 22 EER. It also includes an array of features that optimize sound, and deliver the lowest turndown in flow and highest leaving chilled water capabilities. The Pathfinder is also 100% configurable ...

Installation and Maintenance Manual IMM ACZ/AGZ-4 Group: Chiller Part Number: 331374201 Effective: October 2006 Supersedes: August 2006 Air-Cooled Scroll Condensing Units ACZ 030B through 155B Air-Cooled Scroll Chillers w/ Remote EvaporatorsThe model number of your air conditioner is listed on a metal plate on the side of the unit near the electrical lines running to your home. The key number is the model number - a combination of letters and numbers. Please note that the Product Code or Manufacturer Code is needed for all Bryant and Carrier models. Please note that the Revision ...

I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller. The SN is STNU020400172. Can - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... I have a number (22 units - total) of overhead and wall Hydronic Boiler fed heating units that were damaged ...

The label/tag has faded all I have on file is the model number and the serial number, make. Question Posted By Francisco the Building Engineer on May 3, 2011. Refer to the manufacturer’s website for their HVAC nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data.General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. H3 Series Unit Nomenclature.The first way to calculate tonnage is to just multiply the number of square feet of your room by 0.0016. This will give you AC tonnage value in no time. Suppose you are going to buy an air conditioner for 600 sq ft area, you can calculate AC tonnage by: AC Tonnage = (Area of Room in Square Feets) * 0.0016 tons/sq ft.HFC-134a operates above atmospheric pressure in the require a purge unit to remove non-condensables (air, and compromise chiller performance. Purge units, even refrigerant to the atmosphere, along with the intentional venting of refrigerant since July 1, 1992. eliminates this regular venting of refrigerant.Model Number: AM000013. Description Reviews (0) * McQuay * 60 Ton System * Water Cooled * Model WGZ060AW27-ERIO * Full Controls * Year of Mfg. 2002 * Approximate Foot Print: 9' x 4' x 5' Reviews There are no reviews yet. Be the first to review "Chiller - 60 Ton McQuay 2002" Cancel reply. You must be logged in to post a review.

McQuay Enfinity™ water source heat pumps incorporate the best of our past and the best of what's new. Using feed-back from building owners, consulting engineers, contrac- ... Model CCH (Standard Range - 55°F to 110°F) Model CCW (Extended Range/Geothermal - 25°F to 110°F) Vertical (Floor) Water Source Heat

Serial Number- February, 1999 and later. AUB U 99 05 00148. Plant Identification Abbreviation. AUB = Auburn. U= Unit. Serial Number (build sequence) Week of Manufacture. Year of Manufacture. 08= 2008. 09= 2009 etc. WSHP; WCAX1,2, WCDX1,2, WCMS1,2 Size 019 Designs A, B Rev. J 01/16 RPL 1105106 / Page 4. Nomenclature. Model Number. WCDS 2 019 E Z ...

R. Page 2 / Catalog 1160. Vertical water source heat pump units. Features: m High efficiency. EERs from 10.4 to 12.0 COPs from 3.8 to 4.0. m Performance rated with ISO Standard 13256-1. m Safety agency listed with CETL. m Multiple panels for easy accessibility to compressor and fan sections. m Removable fan motor/wheel assembly. m Two return ...Part Number: 331374601 Effective: March 2008 Supersedes: December 2007 Water-Cooled Centrifugal Chiller ... The McQuay Model WMC Centrifugal Water Chillers are complete, self-contained, automatically controlled, fluid-chilling units featuring oil-free, magnetic bearing compressors. Each unit is completely assembled andSlide out fan (7 to 20 Ton [24.6 to 70.3 kW] units) • For easy access and serviceability. 7.5 to 12.5 Ton [26.4 to 44.0 kW] Unit (15 to 20 Ton [52.8 to 70.3 kW] Unit Not Shown) Gas Heat • Tubular heat exchanger with in-shot burn-ers for maximum heat transfer. • Two-stage gas valve with direct spark ignition provides greater efficiency on 7.5McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps – Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the firstIndustrial Chillers in USA. Subcategory: Chiller. Subcategory 2: Specialty. Listing ID: 58744471. Description. Available for Immediate Delivery! 260 TON McQuay Centrifugal Water Chiller Model PEH063, Used as is, Power washed and painted.

mcquay model number tonnage. Stealth Designer U-Match Cassette Decorative Grille 24K. Trane 10 Ton Package Rooftop #YSC120H3EHA0000 Service First USA.R. Page 2 / Catalog 1160. Vertical water source heat pump units. Features: m High efficiency. EERs from 10.4 to 12.0 COPs from 3.8 to 4.0. m Performance rated with ISO Standard 13256-1. m Safety agency listed with CETL. m Multiple panels for easy accessibility to compressor and fan sections. m Removable fan motor/wheel assembly. m Two return ...Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongMcQuay FMS Series Installation & Maintenance Data (24 pages) Vertical Water Source Heat Pump & Cooling Only Units. Brand: McQuay | Category: Heat Pump | Size: 0.74 MB. Table of Contents. Table of Contents. 1. Model Nomenclature. 2. …York/Quantech – Johnson Controls. Our literature library of data sheets, manuals, & engineering specs is constantly growing. If you need finding product literature call us at 214-321-4200.

technology and quiet operation. Model AGS units utilize a new compressor design utilizing R-134a refrigerant. Superior control is used with the MicroTech II® family of controllers with Open Choices™. They continues McQuay's position of being the only air-cooled screw compressor chiller with superior solid state starters as standard equipment.

mcquay model number tonnage. Stealth Designer U-Match Cassette Decorative Grille 24K. Trane 10 Ton Package Rooftop #YSC120H3EHA0000 Service First USA. McQuay 250 Ton Air Chiller 460 Volt Phase 60. McQuay 250 Ton Air Chiller 460 Volt Phase 60. McQuay 250 Ton Air Chiller 460 Volt Phase 60.These are generally specific use (built to order) and the model number has many more digits/letters. Mcquay is now Daikin. Here is a manual with the model number nomenclature starting on page 5. The actual tons is not listed until position 43. Click Here for Manual. Somewhere on the unit will be a full model number stringCatalog 1108- McQuay Efinity Horizontal Water Source Heat Pumps Page 3 of 76. Enfinity Horizontal Ceiling Water Source Heat Pumps Sizes 007-070 (1/2 to 6 Tons) ModelWCCH(StandardRange:55°Fto110°F) Model WCCW(GeothermalRange:30°Fto110°F) McQuay Enfinity Horizontal Ceiling units are designed for use in multiple floor …General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. 4CX*** Unit Nomenclature.Chiller package includes (4) scroll Copeland mnfg compressors, air-cooled condenser, shell/tube heat exchanger and starter box with related electrical all mounted in an outdoor cabinet. Chiller Model: AGZ065AS4242-ER10-ER, SER#STNU990700115. Unit dimensions: 7'6"x 8' x 8'H. +42 to +60 setpoint. Unit designed to operate on refrigerant R-22 or equal.This Used McQuay 180 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. McQuay AGZ-C: Product Document - Condition - Used Chiller: Previously owned and operated. Was in running condition when removed. ... Model Number: AGZ180; Year: 2009; 180 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-410a (Not ...3-6 Ton DFG Light Commercial 3-5 TON - 13.4 SEER2/11. EER2 3-5 TON - 14.0 SEER/11.5 EER 6 TON - 15.5 IEER/11.2 EER *Complete warranty details available from your local distributor or manufacturer's representative or at www.daikincomfort.com or www.daikinac.comTesla delivered a record-breaking 241,300 electric vehicles in the third quarter, blowing past expectations as other U.S. automakers experienced a drop in sales as the result of a ...DVD players are available today in models ranging from the very basic to the sophisticated, with a varying number of features and options. They are designed for use at home, on the...

Page 83: Medium/High Voltage Starters, 2300V - 7.2Kv. This section contains information on medium voltage, across-the-line and solid state starters as manufactured by Benshaw Inc. for McQuay centrifugal Chillers. Medium voltage starters have similar software (Micro II) and are grouped together in this manual.

The first way to calculate tonnage is to just multiply the number of square feet of your room by 0.0016. This will give you AC tonnage value in no time. Suppose you are going to buy an air conditioner for 600 sq ft area, you can calculate AC tonnage by: AC Tonnage = (Area of Room in Square Feets) * 0.0016 tons/sq ft.

R = 208-230/1/60 62 = 5 Vintage * 10 SEER Size 036, 049 and 060 only. **10 SEER Size 060 only. Table 1: Unit Nameplate Model Number Identifier Unit Nameplate McQuay Model Number CKL18-1L ACU018ARAY CKL24-1L ACU024ARAY CKL30-1L ACU030ARAY CKL36-1L... Page 4: Introduction Replacement Parts substantial fines. View and Download McQuay ALR 110F product manual online. Air-Cooled Reciprocating Water Chillers, 110 to 150 Tons, 380 to 525 kW, R-22, 60 Hertz. ALR 110F chiller pdf manual download. Also for: Alr 120f, Alr 140f, Alr 130f, Alr 135f, Alr 145f, Alr 150f. %PDF-1.6 %âãÏÓ 1371 0 obj > endobj 1386 0 obj >/Filter/FlateDecode/ID[2C57F1C273E3CA498FA7F38C6B63FC5F>]/Index[1371 126]/Info 1370 0 R/Length 97/Prev 1518284/Root ...Cover pictures: Upper unit: Model WSC 087, 500 ton single compressor chiller with factory-mounted starter Lower unit: Model WDC 126, 2000 ton, dual compressor chiller *ETL applies to WSC, WDC, WCC, HSC, HDC only Manufactured in an ISO Certified Facility ©2011 McQuay International. Illustrations and data cover the McQuay International product ...Whether you need to make a warranty claim or find replacement parts, there are plenty of reasons why you may need to find the model number for your GE motor. Here are several helpf...Aug 10, 2023 · The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12. These are generally specific use (built to order) and the model number has many more digits/letters. Mcquay is now Daikin. Here is a manual with the model number nomenclature starting on page 5. The actual tons is not listed until position 43. Click Here for Manual. Somewhere on the unit will be a full model number stringMcQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of

SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200Part Number: 331374601 Effective: March 2008 Supersedes: December 2007 Water-Cooled Centrifugal Chiller ... The McQuay Model WMC Centrifugal Water Chillers are complete, self-contained, automatically controlled, fluid-chilling units featuring oil-free, magnetic bearing compressors. Each unit is completely assembled andSerial Number- February, 1999 and later. AUB U 99 05 00148. Plant Identification Abbreviation. AUB = Auburn. U= Unit. Serial Number (build sequence) Week of Manufacture. Year of Manufacture. 08= 2008. 09= 2009 etc. WSHP; WCAX1,2, WCDX1,2, WCMS1,2 Size 019 Designs A, B Rev. J 01/16 RPL 1105106 / Page 4. Nomenclature. …You may be able to determine the tonnage of your HVAC unit by simply reading the manufacturer's label on your system's outdoor unit. However, most manufacturers don't list tonnage and instead, list BTUs. Converting BTUs to tonnage can be done by simply dividing the BTUs by 12,000. For example, if your HVAC system is 24,000 BTUs, its ...Instagram:https://instagram. ernie isemingertsa pre dallasdalen cuffcarefree dental cost Replacement parts can be obtained by contacting McQuay at 1-800-37-PARTS. When contacting McQuay for service or replacement parts, refer to the model number and serial num-ber of the unit as stamped on the nameplate attached to the unit. GENERAL WARNINGS SCROLL COMPRESSORS Read the following before installing units with scroll compres-sors. fbi cji data must be safeguarded to preventouter space object crossword clue 8 letters Air handling units 3 Air flow (m /h x 1,000) 0 20 40 50 60 70 80 90 100 120 140 D-AHU Professional 750 m3/h up to 144,000 m3/h Modular P › Pre-configured sizes › Plug and play concept › EC Fan technologyView and Download McQuay SWT C Series installation and maintenance manual online. Self-contained Air Conditioning System Vintage Sizes 18 thru 40. SWT C Series air conditioner pdf manual download. Also for: Swt018c, Swt023c, Swt028c, Swt035c, Swt040c. john deere 24t baler specs Have a McQuay 50 ton A/C chiller condenser with 4 scroll compressors, #1 and #3 have a 3/8" tube with schrader on a tee between compressor oil sumps for oil equalizing. #2 and #4 the same. On start up #1 dumps all its oil into #3... then with in 5-8 minutes #3 dumps all its oil into #1... :grin2: I mean the oil sight glass goes empty and fast.That would be a 50ton Roof Top Unit or RTU. It has DX cooling, that is Direct Expansion or simply the Refrigerant cools the air, opposed to a CW unit that has Chilled Water to cool the air. Reply. 07-31-2012, 06:26 AM #5. beenthere.View and Download McQuay ALP-027C instruction manual online.